Series 4060 Gas Chromatographs
Published on : Tuesday 30-11--0001
TThe 4060 Series of Gas Chromatograph (GC) analyzers combine Teledyne's field proven detector technologies with gas chromatography column separation capability. This enables reliable and repeatable of a single or multiple compounds in a stream containing interfering components.
Flame-ionization detector (FID) or thermal conductivity detector (TCD) options enable part-per-billion (ppb), part-per-million (ppm) or percent levels of detection depending on application. The analyzer includes an integral temperature-controlled sample system of 316SS and Teflon construction to provide a suitable sample to the detector. Contact TAI for other available materials.
Features
- Field-proven microprocessor-based electronics with menu-driven functionality
- Easy-to-view 5-digit LED display for readings
- 2 x 20 vacuum fluorescent display for menu options, settings and status
- 0-1 VDC and 4-20mA (isolated) analog outputs and gas identification outputs
- RS-232 duplex digital output
- Two fully-configurable concentration alarms and one system alarm, all with Form-C relay contacts
- Built-in diagnostic capability
- Auto-calibration and remote-calibration ready (integral valves available)
Common Detectable Gases
4060/FID
Acetaldehyde
Benzene
Butane
Carbon Dioxide - (measurement achieved with methanizer)
Carbon Monoxide - (measurement achieved with methanizer)
Ethane
Ethyl Benzene
Ethylene
Hexane
Methane
Methanol
MTBE
Propane
Propylene
Toluene
VOCs
Xylene
4060/TC
Argon (purity and impurity levels)
Carbon Dioxide
Carbon Monoxide
Helium
Hydrogen
Hydrogen Sulfide
Krypton
Nitrogen (purity and impurity levels)
Xenon
Applications
- Ambient benzene, BTEX detection
- Beverage-grade carbon dioxide: detection of ppb benzene, acetaldehyde, methanol and VCM in beverage-grade carbon dioxide to ISBT specification
- Methane / non-methane hydrocarbon monitoring
- Nitrogen or Argon purity
- C1-C4 levels in natural gas or syngas production
- LNG impurity detection
- MTBE monitoring in gasoline
- Hydrogen detection in a mixed fuel gas
Chromatography Software - Tracs™
Tracs™ software developed by TAI provides all features and functionality needed to view and analyze chromatography data. When installed on a PC computer, Tracs™ collects digitized data fed from the analyzer with which it can plot chromatograms, perform analytical calculations, log data, and save information for future use.
Features include:
- Bi-directional communication of analyzer's range, alarm and timing settings which can be remotely uploaded and downloaded
- Acquires real-time raw data for continuous display of chromatograms
- Chromatograms can be superimposed upon one another to verify repeatability
- Elution peaks can be displayed within their own respective timing frames or individually manipulated for optimal peak scrutinization
- Statistical summary including analytical calculation of measurements, distribution of values and deviations
- Data-logging
- Saving and retrieving of digitized data files
It is used in Oil And gas, Chemical Industry.
Teledyne Instruments
United States
Tel: 626-961-9221
Email: [email protected]